• Projector input port name: RS-232C

<At the projector>

<At the computer>

<At the projector>

(PC serial cable)

<At the computer>

Signal Name

Function

GND

Signal wire ground

TD

Transmit data

RD

Receive data

DSR

Data set ready

DTR

Data terminal ready

Communications protocol

• Default baud rate setting: 9600 bps

• Data length: 8 bit
• Parity: None
• Stop-bit: 1 bit
• Flow control: None

ESC/VP21 Commands