EAW NT59 User Manual

Page 29

Advertising
background image

25

8 . 5

A m p l i f i e r S e r v i c e

WARNING: Disconnect the ac mains cable before doing this procedure.
ATTENTION: Déconnectez le cordon du secteur avant d'entamer cette procédure.
ATTENZIONE: Prima di procedere con questa operazione, disconnettere il cavo
d'alimentazione AC.
PRECAUCION: Desconecte el cable de alimentación antes de realizar este proceso.
WARNUNG: Ziehen Sie den Netzstecker aus der Steckdose, bevor Sie mit dieser Prozedur beginnen.

Faulty electronics are serviced by replacing the entire amplifier module.

8 . 5 . 1

A m p l i f i e r M o d u l e s

There are two types of NT amplifier modules:
one for the NT full-range models and one for the subwoofer.

1. Full-range: Input, DSP, 1000 W @ 4 ohm LF amplifier, 500 W @ 4 ohm

HF amplifier, and power supply.

2. Subwoofer: Input, DSP, two 1000 W @ 4 ohm amplifiers, and power supply.

For the NT full-range models (NT2x & NT5x), each amplifier module has the DSP settings
for all models stored in on-board memory. The active settings are determined by on-board
dip switch settings. Thus,amplifier modules for the full-range models are interchangeable
by simply resetting the dip switches for that particular model.

8 . 5 . 2

N T A m p l i f i e r R e p l a c e m e n t M o d u l e s a n d D i p S w i t c h S e t t i n g s

An amplifier replacement module consists of the power amplifiers, DSP board, power
supply, connectors, and indicators; all pre-mounted on the amplifier panel.

Amplifier Module Replacement Part Numbers & Dip Switch Settings
NOTE: If the incorrect DIP switch position is used, poor/incorrect performance will result,
at best sounding bad, at worst causing equipment failure.

8 . 5 . 3

R e p l a c i n g t h e A m p l i f i e r M o d u l e

1. Remove the amplifier module from the other side of the enclosure by removing its12

retaining screws.

2. Disconnect the quick release connector for the transducer cabling.

3. Configure the replacement amplifier for the NT model by setting the dip switch. See

the chart in Section 8.5.2 for the correct settings. The dip switch is located behind the
input receptacles on the backside of the amplifier module.

4. Once the dip switch is programmed, connect the transducer cabling to the

replacement module.

NT Model #

115 V Module

NT26
NT29
NT56
NT59
NTS22

#0016088
#0016088
#0016088
#0016088
#0016090

230 V Module

Dip Switch Settings

#0016584
#0016584
#0016584
#0016584
#0016585

Off
Off
Off
Off
Off

Off
Off
Off
Off
On

Off

On

On

Off

Off

Off
On
Off
On
Off

1

2

3

4

NOTE: Off is up, On is down.

Advertising
This manual is related to the following products: