13.1.6. Alarm registers

(

Reg

−

09

[h]

to

0C

[h]

)

Address

[h]

Function

bit 7

bit 6

bit 5

bit 4

bit 3

bit 2

bit 1

bit 0

09

Minute Alarm

AE

40

20

10

8

4

2

1

0A

Hour Alarm

AE

×

20

10

8

4

2

1

0B

Day Alarm

AE

×

20

10

8

4

2

1

0C

Weekday Alarm

AE

Ч

Ч

Ч

Ч

4

2

1

•

The AIE bit and AF bit can both be set or used when using alarm interrupt function to set interrupt events for dates,

days, hours, minutes, etc.

•

When the current time matches the settings in the above alarm registers, the AF bit's value is "1" and the /INT

pin's status is low to indicate that an alarm interrupt event has occurred.

∗

For details, see "9.3. Alarm Interrupt Function".





13.1.7. Timer setting register

(

Reg

−

0E

[h]

)

Address

[h]

Function

bit 7

bit 6

bit 5

bit 4

bit 3

bit 2

bit 1

bit 0

0E

Timer control

TE

Ч

Ч

Ч

Ч

Ч

TD1

TD0

•

This register is used to control the fixed-cycle timer interrupt function.

•

To use the fixed-cycle timer interrupt function, the TI/TP bits

(Reg

−

01

[h]),

timer register (Reg

−

0F

[h]),

and the

TF and TIE bits are all set or used.

1) TE bit

(

Timer Enable

)

This bit is used to control operation of the fixed-cycle timer interrupt function.
When "1"

is written to this bit, the fixed-cycle timer interrupt function starts operating.

When "0"

is written to this bit, the fixed-cycle timer interrupt function stops operating.

∗

For details, see "9.2. Fixed-cycle Timer Interrupt Function ".

2) TD1,TD0 bits

(

Timer countDown interval select 1,

0

)

These bits specify the fixed-cycle timer interrupt function's countdown period

(source clock).

Four different periods can be selected via combinations of these two bit values.

∗

For details, see "9.2. Fixed-cycle Timer Interrupt Function ".



13.1.8. Down counter for fixed-cycle timer

(

Reg

−

0F

[h]

)

Address

[h]

Function

bit 7

bit 6

bit 5

bit 4

bit 3

bit 2

bit 1

bit 0

0F

Timer

128

64

32

16

8

4

2

1

•

This register is used to set the default (preset) value for the counter. Any count value from 1

(01

h)

to

255

(FFh)

can be set

•

To use the fixed-cycle timer interrupt function, the TE,

TI/TP,

TF,

TIE,

TD1,

and TD0 bits are set and used.

•

When this down counter's count value changes from 01h to 00h, when TF bit

=

"1",

or when the /INT pin is at low

level ("L"), it indicates that a fixed-cycle timer interrupt event has occurred.

•

The current countdown status can be checked by reading this register.

∗

However, since the read data is not held (the data may be changing), to obtain accurate data the countdown

status should be read twice and then compared.

∗

For details, see "9.2. Fixed-cycle Timer Interrupt Function ".