Rx − 8564 lc, 6) example of timer interrupt function setting – Epson RX-8564LC User Manual

Page 34

Advertising
background image

RX

8564

LC

Page

31

ETM12E-01

6) Example of timer interrupt function setting





To next process

Set timer interrupt

function

TE

"

0

"

Zero-clear the TE bit to stop the timer interrupt function.

TF

"

0 "

TIE

"

0

"

Zero-clear the TF bit and TIE bit to cancel the previous timer interrupt output

(/IRQ output).

Initialize counter

3

Set down counter's initial value. (Reg

0F[h])

(Note)

Be sure to set or reset the down counter's initial value each time.

TE

"

1

"

Write "1" to the TE bit to start the timer interrupt function.

(Note)

Before starting the timer interrupt function, be sure to set or reset the

down counter's initial value (see

3 above).

Set TI

/

TP bit

1

Select the operation mode (one-shot interrupt or repeated continuous
interrupts).

1)

When repeated continuous interrupts are selected

Write "1" to the TI

/

TP bits.

2)

When one-shot interrupt is selected

Write "0" to the TI

/

TP bits.

1

Set TIE bit

2

Select event-triggered /INT output (output/do not output interrupt when at

low level).

1) Output interrupt when at low level

Write "1" to the TIE bit.

2)

Do not output interrupt when at low level

Write "0" to the TIE bit.

2

Set TD1,

TD0 bit

Set the timer's countdown period (= source clock).

Select using a combination of TD1 and TD0 bit values.

i.

C

anc

e

l t

im

e

r

in

te

rr

u

pt

func

ti

on

ii.

S

e

t t

im

e

r

in

te

rru

p

t

func

ti

on

iii.

S

tar

t

ti

m

e

r i

n

te

rr

u

p

t f

u

n

c

ti

on

3