Rx − 8564 lc, Ac electrical characteristics, Item symbol condition min. typ. max. unit – Epson RX-8564LC User Manual

Page 9

Advertising
background image

RX

8564

LC

Page

6

ETM12E-01

8.2. AC electrical characteristics

*

Unless otherwise specified, GND

=

0

V

,

V

DD

=

1.8

V

to

5.5

V

,

Ta

=

40

°

C

to

+85

°

C

Item

Symbol

Condition

Min.

Typ.

Max.

Unit

SCL clock frequency

f

SCL

400

kHz

Start condition set-up time

t

SU; STA

0.6

µ

s

Start condition hold time

t

HD; STA

0.6

µ

s

Data set-up time

t

SU; DAT

100

ns

Data hold time

t

HD; DAT

0

ns

Stop condition set-up time

t

SU; STO

0.6

µ

s

Bus free time between a STOP
and START condition

t

BUF

1.3

µ

s

SCL "L" time

t

LOW

1.3

µ

s

SCL "H" time

t

HIGH

0.6

µ

s

SCL and SDA rise time

tr

0.3

µ

s

SCL and SDA fall time

tf

0.3

µ

s

Tolerance spike time on bus

t

SP

50

ns


Timing chart

t

HD ; DAT

t

SU ; DAT

t

HD ; STA

t

LOW

t

HIGH

1 / f

SCL

t

r

t

f

t

SU ; STA

SDA

SCL

START

CONDITION

(S)

BIT 7

MSB

(A7)

BIT 6

(A6)

ACK

(A)

Protocol

t

BUF

t

SU ; STO

STOP

CONDITION

(P)

START

CONDITION

(S)

(P)

(A)

t

HD ; STA

t

SU ; STA

(S)

BIT 0

LSB

(R/W)

(S)

t

SP


Note : I

2

C access time between a START and a START condition or between a START and a STOP condition to this

device must be less than one second.