Power and power management

© 2007 Eurotech Ltd Issue E

77

Power savings

Use the table below to estimate power savings that can be achieved by shutting down features of
the VIPER, or putting the VIPER to sleep.

Power

saving

mode

Performance

mode

CPU Ethernet USB Audio Serial

Current

saving

±3mA

Total

current

±3mA

Total

power

±15mW

Current

saving

±3mA

Total

current

±3mA

Total

power

±15mW

- - - - - 0mA 325mA

1625mW

0mA 334mA

1670mW

- - - -

Sleep

25mA 300mA

1500mW

25mA 309mA

1545mW

- - -

Sleep

- 38mA 287mA

1435mW

38mA 296mA

1480mW

- - -

Sleep

Sleep

64mA 261mA

1305mW

64mA

270mA 1350mW

- -

Sleep

- - 37mA 288mA

1440mW

37mA

297mA 1485mW

- -

Sleep

-

Sleep

62mA 263mA

1315mW

62mA

272mA 1360mW

- -

Sleep

Sleep

- 77mA 248mA

1240mW

77mA

257mA 1285mW

- -

Sleep

Sleep

Sleep

100mA

225mA

1125mW

100mA

234mA 1170mW

- Sleep - - - 108mA 217mA 1085mW

108mA

226mA 1130mW

- Sleep - - Sleep 131mA 194mA 970mW

131mA

203mA 1015mW

- Sleep - Sleep - 146mA 179mA 895mW

146mA

188mA 940mW

- Sleep - Sleep

Sleep 172mA 155mA 775mW

172mA

162mA 810mW

- Sleep

Sleep - - 143mA 182mA 910mW

143mA

191mA 955mW

- Sleep

Sleep - Sleep 167mA 158mA 790mW

167mA

167mA 835mW

- Sleep

Sleep

Sleep - 181mA 144mA 720mW

181mA

153mA 765mW

- Sleep

Sleep

Sleep

Sleep 205mA 120mA 600mW

205mA

129mA 645mW

Sleep Sleep Sleep Sleep Sleep 276mA

49mA

245mW 285mA 49mA

245mW

VL