JP1 – RS485/422 configuration jumpers

Connector: Oupiin 2011-2x5GSB/SN, 10-way, 2.54mm (0.1”) x 2.54mm (0.1”) dual row
through-hole unshrouded header

Ref Pin

Signal

name Pin

Signal

name

1 PL4_RX5-

2 PL4_RX5+

3 RX5-

4 RX5+

5 PL4_RX5/TX5- 6 PL4_RX5/TX5+

7 PL4_RX5+

8 RX5-_120R

JP1

9 PL4_RX5/TX5+

10 RX5/TX5-_120R

JP2 – LCD voltage select jumper

Connector: Oupiin 2011-1x3GSB/SN, 3-way, 2.54mm (0.1”) single row through-hole
header

Ref Pin

Signal

name

1 5V

2

LCD Logic Supply

JP2

3 3.3V

JP3 – User configuration and reset jumper

Connector: Oupiin 2011-2x3GSB/SN, 6-way, 2.54mm (0.1”) x 2.54mm (0.1”) dual row
through-hole unshrouded header

Ref Pin

Signal

name Pin

Signal

name

1 GND

2 USER_CONFIG1

3 GND

4 Reserved

JP3

5 GND

6 RESETSW

JP4 – Battery jumper

Connector: Oupiin

2011-1x2GSB/SN

, 2-way, 2.54mm (0.1”) single row through-hole

header

Ref Pin

Signal

name Pin

Signal

name

JP4

1

Battery Backup
Switch Input

2 Battery

+

Terminal

6

5

1

2

10

9

2

1

1

3

6

5

1

2

VL