Flooded Engine

Bank Angle Sensor Ignition Cut-off System

Starting & Stopping the Engine

Basic Operation & Riding

If Your Engine Quits or Won’t

Start,

If the engine fails to start after repeated attempts, it may be flooded with
excess fuel. To clear a flooded engine:

Leave the engine stop switch set to RUN (

).

Open the throttle fully.
Press the start button for 5 seconds (or operate the recoil starter
several times).
Follow the normal starting procedure.
If the engine starts, then open the throttle slightly if idling is unstable.
If the engine does not starts, wait 10 seconds, then follow steps

again.

If the engine still won’t start, refer to

page

.

Your vehicle’s banking (lean angle) sensor system is designed to
automatically stop the engine if the vehicle is overturned.

Before restarting the engine, you must turn the ignition switch to the
OFF (

) position and then back to ON (

). The engine will not

restart until you perform this procedure.