+DELTA-T

Operation and settings

■

Turn unit on.

■

Load oven rack.

■

Insert IQT Sensor probe.

■

DO NOT select cooking mode. Deactivate if mode has already been selected.

■

Press IQT key: (“+PROFILE” appears in the adjacent display.) Use Central Dial
to select +DELTA-T.

■

Press PROG/START key to activate program. Pre-selected settings will appear
on the TEMPERATURE and IQT Sensor displays.

■

Press TEMPERATURE key and use Central Dial to enter desired Delta
temperature–68-140°F (20-60°C).

■

Press IQT Sensor key and use Central Dial to enter desired core
temperature–110-210°F (45-99°C).

■

Press PROG/START to confirm and initiate +Delta-T cooking.

During operation

■

Since +Delta-T cooking operates in Moist Heat mode, the ClimaPlus window
will display a blue bar and the Moist Heat mode key will be active during the
cooking cycle.

■

The actual core temperature will appear in the display next to “done” core
temperature.

■

The control panel is not accessible during operation except for the following
functions (may depend on model.)

•

IQT, HACCP (all LCS and LCG models)

•

Half Energy (all LCS Electric models)

•

Half Fan Speed (all LCS Electric models and the LCG-40 Gas)

■

Opening the door during operation merely interrupts the cooking process.
When door is closed, all functions resume.

■

To stop the IQT +Delta-T program altogether, it is necessary to turn off the unit.

NOTE: For a Delta-T Cooking program without IQT Logic see “Special Functions:
Delta-T Cooking”, page 40.

COOKING
FUNCTIONS

IQT +DELTA-T
COOKING

continued