Industry Standard
Compliance

ACPI V2.0 Compliant

PCI 2.2 Compliant

PXE Support

WOL Support

Microsoft® Logo certifications

IPMI 2.0

DCMI 1.0

SMASH CLP compliant

Security

Power-on password

Setup password

Diskette boot control

Secure Sockets Layer (SSL)

Secure Shell (SSH)

Security - Trusted
Platform Module

The TPM (Trusted Platform Module) is a microcontroller chip that can securely store artifacts used
to authenticate the server platform. These artifacts can include passwords, certificates and
encryption keys. Windows® BitLocker™ Drive Encryption (BitLocker) is a data protection feature
available in Windows Server® 2008. BitLocker leverages the enhanced security capabilities of a
Trusted Platform Module (TPM) version 1.2. The TPM works with BitLocker to help protect user
data and to ensure that a server running Windows Server 2008 has not been tampered with while
the system was offline.

NOTE: For more information about TPM, including a white paper, go to:

http://www.hp.com/go/TPM

NOTE: ProLiant OS pre-installed units will come with the partition required for TPM deployment.
NOTE: The TPM key is unique to every TPM deployed server and must be retained. Misplacing or
losing the key could result in data loss.

Server Power Cords

One 6' Highline (IEC-IEC) power cord ships standard

NOTE: HP ProLiant DL servers no longer ship standard with NEMA power cords (163719-002)
that allow connection to 110V US wall outlets in a home or office. ProLiant DL servers are
primarily connected to PDU's in data center racks so they now ship standard with only a PDU
power cord (416151-B21). If a user wishes to power a ProLiant DL server using a 110V receptacle
(NEMA-15), the NEMA power cord (227099-001) must be ordered separately.

If customers require a local power cord, they can check the power cord matrix for the appropriate
cord. Please see the following power cord matrix:

http://www.hp.com/go/powercordmatrix

.

UPS and PDU Power
Cord Matrix

Please see the UPS and PDU cable matrix's on the HP Power Protection and Management page.
Under Power Cords, click on the "HP Power Cord Matrix" link. That link will list cable descriptions,
requirements, and specifications for UPS and PDU units. Please see the following link:

www.hp.com/products/powercords

.