Isle royale wood stove, Installation considerations warning, A. hearth rotection re uirements – Hearth and Home Technologies QUADRA-FIRE 823-0170 - MBK User Manual

Page 11

Advertising
background image

Isle Royale Wood Stove

R

March

21,

2013

250-5763F

Page

11

CANADA

203mm (8")

203mm

(8")

203mm

(8")

457mm (18")

1219mm
(48")
Minimum

1137mm (44-3/4")

Minimum

16" from glass - std legs

8"

USA

Fuel loading door

36-3/4"

Minimum

39-1/4"

Minimum

must extend
length of flue and
2" (51mm)
beyond each
side of pipe

USA Re uired
CANADA Recommended

16"

optional coverage

optional

coverage

optional

coverage

8”

36-9/16"

required coverage

38-5/8"

51"

30-3/8"

51"

USA Installations

fuel loading door

A. Hearth rotection Re uirements

FLOOR ROTECTION: Floor protector must be non-
combustible material, extending beneath heater and to the
IURQWVLGHVDQGUHDUDVLQGLFDWHG7KHÀRRUPXVWEHQRQ
combustible or otherwise adequately protected from radiant
heat given off by the unit and from sparks and falling embers.
$OD\HURIWKLQEULFNRUFHUDPLFWLOHRYHUDFRPEXVWLEOHÀRRU
LVQRWVXI¿FLHQW
In US installations iWLVQHFHVVDU\WRLQVWDOODÀRRUSURWHF-
tor of 1 inch ("k" value= .45) thick metal clad millboard or
equivalent at least 16 inches (406mm) in front of glass and 8
inches (203mm) to both sides of the fuel loading door. Open
the door and measure 8 inches (203mm) from the side edge
of the opening in the face of the appliance. *

See exception.

In Canada  VLPLODU ÀRRU SURWHFWLRQ PXVW EH SURYLGHG 
inches (457mm) in front and 8 inches (203mm) from the
sides and rear of the stove. *

See exception.

E CE TION:  1RQFRPEXVWLEOH ÀRRU SURWHFWLRQV PXVW

H[WHQGEHQHDWKWKHÀXHSLSHZKHQLQVWDOOHGZLWKKRUL]RQWDO
venting and extend 2 inches (51mm) beyond each side.
See Figure 11. .

Installation Considerations

WARNING

Fire Risk.
‡ +HDUWKSDGVPXVWEHLQVWDOOHGH[DFWO\DV

VSHFLILHG

+LJKWHPSHUDWXUHVRUKRWHPEHUVPD\LJQLWH
FRQFHDOHGFRPEXVWLEOHV

Figure 11.1

Figure 11.

Figure 11.

Figure 11.

Advertising