Isle o ale oo to e – Hearth and Home Technologies QUADRA-FIRE 823-0170 - MBK User Manual

Page 15

Advertising
background image

Isle o ale oo to e

R

March

21,

2013

250-5763F

Page

15

i

le

Site constructed for masonry chimney installation:

o ponents

 ‡ $ PLQLPXP OHQJWK RI  LQFKHV >PP@ ORQJHU IRU

thicker walls) of solid insulated factory-built chimney
OHQJWKFRQVWUXFWHGWR8/7\SH+7LQFK PP 
inside diameter. Chimney needs to extend a minimum
of 2 inches (51mm) from the interior wall and a mini-
mum of 1 inch (25mm) from the exterior wall.

 ‡ :DOOVSDFHUWULPFROODUDQGZDOOEDQGWR¿WVROLGSDFN

chimney selected.

 ‡ 0LQLPXPLQFK PP GLDPHWHUFOD\OLQHUVHFWLRQ LI

not already present in chimney) and refractory mortar.

ir learan es

‡ 0DVRQU\FKLPQH\FOHDUDQFHPXVWPHHW1)3$PLQL-

mum requirement of 2 inches (51mm) to sheet metal
supports and combustibles.

‡ 0LQLPXPRILQFK PP FOHDUDQFHDURXQGWKHFKLP-

ney connector.

‡ 7RS RI ZDOO RSHQLQJ LV D PLQLPXP RI  LQFKHV

(343mm) from ceiling or 4-1/2 inches (114mm) below
PLQLPXP FOHDUDQFH VSHFL¿HG E\ FKLPQH\ FRQQHFWRU
PDQXIDFWXUHU1)3$PLQLPXPYHUWLFDOFOHDUDQFHRI
18 inches (457mm) from chimney connector and ceil-
ing or minimum recommended by chimney connector
manufacturer.

Figure 1 .1.

Instru tions

1. Open inside wall at proper height for the chimney con-

nector to entry the masonry chimney.

Figure 1 .1

2. Entry hole to masonry chimney must be lined with an 8

inch (203mm) minimum diameter clay liner, or equiva-
lent, secured with refractory mortar.

3. Construct a 17 inch x 17 inch (432mm x 432mm) out-

side dimension frame from 2 x 2 framing lumber to
¿WLQWRZDOORSHQLQJ,QVLGHRSHQLQJRIIUDPHVKRXOG
be no less than 14 inch x 14 inch (356mm x 356mm).
Figure 1 .1.

 $WWDFKWKHZDOOVSDFHUWRWKHFKLPQH\VLGHRIWKHIUDPH

5. Nail the frame into the wall opening. The spacer should

be on the chimney side.

6. Insert the section of the solid insulated chimney into

the outer wall of the masonry chimney.

7. Tightly secure the length of the solid insulated chimney

with the wall band to the masonry chimney.

8. Insert a section of chimney connector into the chimney.

Make sure it does not protrude past the edge of the
clay chimney liner inside the chimney.

9. Seal the end of the chimney connector to the clay liner

with refractory mortar.

10. Install trim collar around the sold pack chimney section.

Figure 1 .1

Trim Collar

Chimney Section

with 2 inch

(51mm)

Clearance to

Combustibles

Chimney

Connector

Fire Clay Flue

Liner

with Airspace

Masonry

Chimney

Wall Band to

Secure Chimney

Section

Wood Studs Used

for Framing - Spaced

2 inch (51mm)

clearance from

Masonry Chimney

Wall Spacer

Figure 1 .2 oli a

i ne wit etal upports

as a i

le

Fire Risk.
Do NOT pack insulation or other combustibles between
spacers.
‡ $/:$<6PDLQWDLQVSHFL¿HGFOHDUDQFHVDURXQG

venting and spacers.

‡ ,QVWDOOVSDFHUVDVVSHFL¿HG
Failure to keep insulation or other material away from

YHQWSLSHPD\FDXVH¿UH

I

1.5”

1.0”

2.0”

2.0”

1.5”

14.0” ID

17.0” OD

ceiling

Minimum18.0”

NFPA 211

13.5” below ceiling to top
of opening

1.0”

8.0”

1.5 2x2 framing stud

2.0 min air clearance

1.0 min air clearance
4.5

or top of opening is a min.of
4.5” below min.clearance
specified by connector mfg.

Center of Hole

Thimble

C

L

C

L

Wall

Include depth
of hearth pad

Advertising