HP AA-RTDRB-TE User Manual

Page 127

Advertising
background image

Error Messages

127

Embedded Web Server User Guide

Error 117: Port Speeds

Cannot be Set at Higher

Data Rate than Switch

Speed

This request cannot be

completed because the

requested port speed is

faster than the

currently-configured

switch speed.

The switch speed should

first be configured to

accommodate changes in

the configured port

speed. The ports cannot

operate at a faster rate

than the switch, itself.

Update the switch speed

and resubmit the request.

Error 118: Invalid Port

Speed

This request cannot be

completed because the

requested port speed is

not recognized for this

product.

Port speeds may be set to

1 Gbps or 2 Gbps.

Update the port speed

and resubmit the request.

Error 119: Switch Speed

Not 2 Gb/sec

This request cannot be

completed because the

switch speed has not been

set to 2 Gbps.

The switch speed must be

set to 2 Gbps in order to

accommodate a port

speed of 2 Gbps. Update

the switch speed and

resubmit the request.

Error 134: Invalid

Membership List

Generic message to

indicate a problem in

either the switch binding

or fabric binding

membership list.

Be sure that the

membership list submitted

does not isolate a switch

already in the fabric. If

this is not the case, the

user needs to be aware of

all fabric security rules

and make sure that the list

submitted adheres

appropriately.

Error 135: Invalid

Number of Fabric

Membership List Entries

The number of fabric

members submitted

exceeds the maximum

allowable entries of 31.

The number of entries in

the fabric membership list

is limited to the total

number of domain ID's

available to the fabric.

Make sure that the list

(including the managed

switch) contains no more

than 31 entries.

Table 9: Embedded Web Serve Messages (Continued)