WARNING

Electrical shock hazard

Electrically ground dishwasher. Connect ground wire to

green ground connector in terminal box. Do not use

an extension cord. Failure to ground dishwasher can

result in death, fire, or electrical shock.

1. Install strain relief and route direct wire so that it does not

touch dishwasher motor or lower part of dishwasher tub. Pull

direct wire “A” through hole in terminal box.

hElpful TIp:

Select the proper size twist-on connectors to connect your

household wiring to 16-gauge dishwasher wiring.

Insert wire ends into twist-on connector. Do not pre-twist

bare wire. Twist connector. Gently tug on wires to be

sure both are secured.

2. Connect the wire “b” as follows using twist-on

connectors “C” sized to connect direct wire to

16-gauge dishwasher wire:
from bare ground wire “D” into a U-shaped hook.

Wrap ground wire hook clock- wise around ground

connector “E” and under the washer “f”. Securely

tighten ground connector “E” and under the washer

“f”. Securely tighten ground connector “E”. Do not untie knot in the wires.

3. Tighten clamp connector or conduit connector screws “G”.
4. Reinstall terminal box cover “H” with wires inside

terminal box. Go to step 5. The cover must be outside the

box on the right side. Make sure no wires are pinched by

cover. Do not leave the box without the cover.