Henny Penny 600 EN User Manual

Page 17

Advertising
background image

Model 500/561/600

Timer Programming
1.

Anytime the cook time is displayed, press under the appropri-
ate display to change the cook time.

Set-Point Temperature Programming
1.

Press

once to view the actual shortening temperature and

press

again to view the set-point temperature.

2.

While the set-point temperature is in the display, press

to change the set-point temperature.

If “LOCK” shows in display when pressing ,
the controls are locked and must be unlocked before changing
the time or set-point temperature. See C1000 Special
Programming Section.

3-6. C1000 PROGRAMMNG
INSTRUCTIONS

3-7. C1000 SPECIAL

PROGRAMMNG

Special Programming is used to set the items below:

ƒ

Fahrenheit or Celsius

ƒ

Initialize System

ƒ

Lock or Unlock Controls

ƒ

Fryer Type – Open or Pressure

ƒ

Heat Source – Electric; Gas w/electronic ignition

ƒ

Vat Type - Full or Split

ƒ

Oil Type - Solid or Liquid

1. To enter Special Programming, turn off power switch

(either side). Press and hold and turn the power
switch back on.

2. “SPEC” “PROG” followed by, “DEG” “°F” or “°C”.

Use

to choose “°F” or “°C”.

3. Press

and “INIT” shows in the display.

Press and hold

and display shows “In-3”,

“In-2”, “In-1” followed by “Init Sys” “DONE DONE”. The
controls now are reset to factory parameters, the time set to
0:00 and temperature 190°F or 88°C.

4. Press

and “LOCK” or “UNLOCK” shows in the dis-

plays. Use

to choose “LOCK” or “UNLOCK.

5. Press

and “FRYR” shows in left display and the right

display should show “PRES”. Use to change from
“OPEN” to “PRES” if needed.