Caution, Vent information and diagrams, Warning – Heat & Glo Fireplace Soho24B 2137-900 User Manual

Page 11

Advertising
background image

11

Heat & Glo • Soho24B • 2137-900 Rev. P • 8/12

Figure 5.2 SLP Pipe Effective Length

Fire Hazard.

Explosion Risk.

Asphyxiation Risk.

Do NOT connect this gas appliance to a chimney
fl ue serving a separate solid-fuel or gas burning
appliance.

• Vent this appliance directly outside.

• Use separate vent system for this appliance.

May impair safe operation of this appliance or
other appliances connected to the fl ue.

CAUTION

ALL vent confi guration specifi cations MUST be followed.

• This product is tested and listed to these specifi cations.

• Appliance performance will suffer if specifi cations are not

followed.

B. Use of Elbows

Diagonal runs have both vertical and horizontal vent as-
pects when calculating the effects. Use the rise for the
vertical aspect and the run for the horizontal aspect (see
Figure 5.1).

Two 45º elbows may be used in place of one 90º elbow. On
45º runs, one foot of diagonal is equal to 8-1/2 (216 mm)
inches horizontal run and 8-1/2 (216 mm) inches vertical
run. A length of straight pipe is allowed between two 45º
elbows (see Figure 5.1).

Figure 5.1

5

5

Vent Information and Diagrams

A. Vent Table Key

The abbreviations listed in this vent table key are used in
the vent diagrams.

C. Measuring Standards

Vertical and horizontal measurements listed in the vent
diagrams were made using the following standards.

1. Pipe measurements are shown using the effective length

of pipe (see Figure 5.2).

2. Horizontal terminations are measured to the outside

mounting surface (fl ange of termination cap) (see
Figure 4.1).

3. Vertical terminations are measured to bottom of termi-

nation cap.

4. Horizontal pipe installed level with no rise.

Symbol

Description

V

1

First section (closest to appliance) of vertical length

V

2

Second section of vertical length

H

1

First section (closest to appliance) of horizontal length

H

2

Second section of horizontal length

Horizontal

Vertical

8-1/2 in.

8-1/2 in.

12 in.

WARNING

Effective Height/Length

Pipe

inches

mm

SLP4

4

102

SLP6

6

152

SLP12

12

305

SLP24

24

610

SLP36

36

914

SLP48

48

1219

SLP6A

2 - 6

51 - 152

SLP12A

2 - 12 51 - 305

Effective

Height/
Length