Heat & Glo Fireplace Soho24B 2137-900 User Manual
Page 15
Advertising
15
Heat & Glo • Soho24B • 2137-900 Rev. P • 8/12
Figure 5.8
2. Top Vent - Vertical Termination - (continued)
Three Elbows
V
1
Minimum
H
1
+ H
2
Maximum
V
2
V
1
+ V
2
Minimum
Elbow only
1/2 ft.
152 mm
*
*
*
1/2 ft.
152 mm
1 ft.
305 mm
*
*
*
1-1/2 ft.
457 mm
2 ft.
610 mm
*
*
*
2-1/2 ft.
762 mm
4 ft.
1.2 m
*
*
*
3-1/2 ft.
1.1 m
6 ft.
1.8 m
*
*
*
4-1/2 ft.
1.4 m
14 ft.
4.3 m
*
*
*
H
1
+ H
2
= 14 ft (4.3 m) Maximum
V
1
+ V
2
+ H
1
+ H
2
= 37 ft (11.3 m) Maximum
*No specifi c restrictions on this value EXCEPT V1 + V2 + H1 + H2 cannot
exceed 37 ft. (11.3 m)
INSTALLED
HORIZONTALLY
H
1
H
2
V
1
V
2
Advertising