Heat & Glo • Soho24B • 2137-900 Rev. P • 8/12

30

C. IntelliFire Ignition System Wiring

This appliance requires a 110 VAC supply to the appliance
junction box for operation. A wiring diagram is shown in
Figure 10.1.

This appliance is equipped with an IntelliFire control valve
which operates on a 3 volt system.

This appliance is supplied with a 3 volt AC transformer
which requires the installation of the supplied junction box.
It is highly recommended that the junction box be installed
at this time to avoid reconstruction.

CAUTION

Label all wires prior to disconnection when servicing controls.
Wiring errors can cause improper and dangerous operation.
Verify proper operation after servicing.

Shock hazard.
• Replace damaged wire with type 105º C

rated wire.

• Wire must have high temperature insulation.

WARNING

A. Recommendation for Wire

This appliance requires 110-120 VAC be wired to the
junction box either for proper operation of the appliance.

10

10

Electrical Information

NOTE: This appliance must be electrically wired and grounded
in accordance with local codes or, in the absence of local
codes, with National Electric Code ANSI/NFPA 70-latest
edition
or the Canadian Electric Code, CSA C221.1.

B. Connecting to the Appliance

Wire 110V to electrical junction box.

Do NOT wire 110V to valve.

Do NOT wire 110V to wall switch.

• Incorrect wiring will damage millivolt valves.

• Incorrect wiring will override IPI safety lockout

and may cause explosion.

WARNING

Note: This appliance must be electrically wired and grounded
in accordance with local codes or, in the absence of local
codes, with National Electric Code ANSI/NFPA 70-latest
edition
or the Canadian Electric Code, CSA C221.1.

• If using thermostat use one compatible with a millivolt

gas valve system.

• Follow parameters for locating thermostat (see individ-

ual thermostat instructions) to ensure proper operation
of appliance.

• Use low resistance thermostat wire for wiring from igni-

tion system to the wall switch and thermostat.

• Keep wire lengths as short as possible by removing any

excess wire length.

• Low voltage and 110 VAC voltage cannot be shared

within the same wall box.

• A 110-120 VAC circuit for this product must be protected

with ground-fault circuit-interrupter protection, in
compliance with the applicable electrical codes, when
it is installed in locations such as in bathrooms or near
sinks.