Maintenance and inspection, Warning – Hitachi DH 45MR User Manual

Page 17

Advertising
background image

17

English

MAINTENANCE AND INSPECTION

WARNING:

Be sure to switch power OFF and disconnect the plug from the
receptacle during maintenance and inspection.

1. Inspecting the drill bits

Since use of a dull tool will cause motor malfunctioning and degraded efficiency, replace
the drill bit with a new one or resharpening without delay when abrasion is noted.

2. Inspecting the screws

Regularly inspect all screws and ensure that they are properly tightened. Should any of
the screws be loose, retighten them immediately.

WARNING:

Using this Rotary Hammer with loosen screws is extremely dangerous.

3. Maintenance of the motor

The motor unit winding is the very “heart” of the power tool. Exercise due care to
ensure the winding does not become damaged and/or wet with oil or water.

4. Inspecting the carbon brushes: (Fig. 20)

The motor employs carbon brushes which are consumable parts. When they become
worn to or near “wear limit”, it could result in motor trouble. When an auto-stop carbon
brush is equipped, the motor will stop automatically. At that time, replace both carbon
brushes with new ones which have the same carbon brush Nos. shown in the figure.
In addition, always keep carbon brushes clean and ensure that they slide freely within
the brush holders.

CAUTION: Using this Rotary Hammer with a carbon brush which is worn in excess of

the wear limit will damage the motor.

NOTE: Use HITACHI carbon brush No.71 indicated in Fig. 20

⅜ Replacing carbon brushes:

(For parts name, refer to Fig. 1)
Loosen the two set screws and remove the tail cover. Remove the brush caps and carbon
brushes. After replacing the carbon brushes, tighten the brush caps securely and to
install the tail cover with securely tightening two set screws.

Fig. 20

Wear limit

No. of carbon brush

0.28" (7 mm)

0.67" (17 mm)

71

01Eng_DH45MR_US

4/4/06, 10:23

17

Advertising