OM-925 Page 16

5-7. Selecting A Location And Connecting Input Power For 230 VAC Model

1

Rating Label

Supply correct input power.
2

Plug (NEMA 6-50P)

3

Receptacle (NEMA 6-50R)

Connect plug to receptacle.
4

Line Disconnect Device

See Section 5-8.
Y Special installation may be

required where gasoline or

volatile liquids are present −

see NEC Article 511 or CEC

Section 20.

ssb2.2* 1/94 − 803 713-B

18 in (457 mm) of

space for airflow

L1

L2

230 VAC, 1

Y Always connect

grounding

conductor first.

= GND/PE

3

Y Do not move or operate unit

where it could tip.

2

L1

L2

4

1

Advertising