OM-925 Page 17

5-8. Electrical Service Guide For 230 VAC Model

Input Voltage

230

Input Amperes At Rated Output

20

Max Recommended Standard Fuse Or Circuit Breaker Rating In Amperes

Circuit Breaker

1

, Time-Delay

2

25

Normal Operating

3

30

Min Input Conductor Size In AWG

14

Max Recommended Input Conductor Length In Feet (Meters)

67

(20)

Min Grounding Conductor Size In AWG

14

Reference: 1999 National Electrical Code (NEC)

1 Choose a circuit breaker with time-current curves comparable to a Time Delay Fuse.
2 “Time-Delay” fuses are UL class “RK5” .
3 “Normal Operating” (general purpose − no intentional delay) fuses are UL class “K5” (up to and including 60 amp), and UL class “H” ( 65 amp and

above).

5-9. Installing Wire Spool And Adjusting Hub Tension

When a slight force is needed

to turn spool, tension is set.

1/2 in

Tools Needed:

803 012 / 803 013 -B / Ref. 802 971-C

Installing 8 in (203 mm) Wire Spool

Installing 4 in (102 mm) Wire Spool

When a slight force is needed

to turn spool, tension is set.

Retaining ring used

with 8 in (203 mm)

spool only.

Adapter used with

8 in (203 mm)

spool only.