Hearth and Home Technologies HST-48D User Manual

Page 23

Advertising
background image

23

Outside Air

Hood

Outside Air

Plate

Assembly

2 Wire Ties

Flexible Duct

(not supplied)

Figure 7.5 Outside Air Installation

E. Install Outside Air Kit

• Keep duct runs short and straight to minimize restriction.

A small dip is acceptable for a cold air trap.

• The outside air kit must be installed using the outside

air cover (see Dimensions, Section 13.A. for location).

• Locate the outside air hood in a clear area, preferably

into prevailing wind during the heating season. Refer to
Figure 5.2.

• Install as shown in Figures 7.3, 7.4 and 7.5.
• The air duct may be run vertically.
• The outside air hood must be at least 3 ft (.91 m) below

the top of the uppermost chimney section.

CAUTION! Risk of Fire or Asphyxiation! DO NOT

draw outside combustion air from wall, fl oor or ceiling
cavity, or enclosed spaces such as an attic or garage.

DO NOT place outside air hood close to exhaust
vents or chimneys. Fumes or odor could be drawn
into the room through the fi replace.

• Locate outside air inlet to prevent blockage from

leaves, snow/ice, or other debris. Blockages could
cause combustion air starvation.