OM-227 978 Page 14

5-6. Selecting A Location And Connecting Input Power

Y Special installation may be

required where gasoline or

volatile liquids are present −

see NEC Article 511 or CEC

Section 20.

Y Installation must meet all Na-

tional and Local Codes −

have only qualified persons

make this installation.

Y Disconnect and lockout/tag-

out input power before con-

necting input conductors

from unit.

Y Always connect green or

green/yellow conductor to

supply grounding terminal

first, and never to a line ter-

minal.

1

Rating Label

Supply correct input power.
2

Black And White Input

Conductor (L1 And L2)

3

Green Or Green/Yellow

Grounding Conductor

4

Input Power Cord.

5

Disconnect Device (switch

shown in the OFF position)

6

Disconnect Device Grounding

Terminal

7

Disconnect Device Line

Terminals

Connect green or green/yellow

grounding conductor to disconnect

device grounding terminal first.
Connect input conductors L1 and

L2 to disconnect device line

terminals.
8

Receptacle (NEMA 6-50R)

Connect receptacle as shown.
9

Over-Current Protection

Select type and size of over-current

protection using Section 5-7 (fused

disconnect switch shown).
Close and secure door on disconnect

device. Remove lockout/tagout

device, and place switch in the On

position.
10 Plug (NEMA 6-50P)
Connect plug to receptacle.

ssb2.2* 1/94 − 804 687-A

18 in (457 mm) of

space for airflow

L1

L2

230 VAC, 1

8

Y Do not move or operate

unit where it could tip.

10

1

1

=GND/PE Earth Ground

2

L1
L2

5

4

3

6

7

9