5-7. Electrical Service Guide

Input Voltage

230

Input Amperes At Rated Output

24

Max Recommended Standard Fuse Or Circuit Breaker Rating In Amperes

Circuit Breaker

1

, Time-Delay

2

25

Normal Operating

3

35

Min Input Conductor Size In AWG

14

Max Recommended Input Conductor Length In Feet (Meters)

55

(17)

Min Grounding Conductor Size In AWG

14

Reference: 1999 National Electrical Code (NEC)

1 Choose a circuit breaker with time-current curves comparable to a Time Delay Fuse.
2 “Time-Delay” fuses are UL class “RK5” .
3 “Normal Operating” (general purpose − no intentional delay) fuses are UL class “K5” (up to and including 60 amp), and UL class “H” ( 65 amp and

above).