3. air-cooled gun connections – Hobart Welding Products OM-1594 User Manual
Page 19
Advertising
OM-1594 Page 15
4-3.
Air-Cooled Gun Connections
Ref. 801 577-A / 801 564 / Ref. 151 666-A
1
Gun Control Cable
Insert plug into Gun Control
receptacle, and tighten threaded
collar.
2
Gas Hose
3
Reed Relay
4
Weld Cable
5
Weld Cable Terminal In
Feeder
Route weld cable from welding
power source through reed relay to
weld cable terminal in feeder and
connect to weld cable terminal.
6
Gun Connector
7
Gun Securing Knob
8
Gun Connector Block
Loosen gun securing knob, and
insert gun connector through Wire
opening until it bottoms against
block. Tighten knob. Close and
latch door.
Tools Needed:
9/16, 3/4 in
5
4
8
7
6
1
2
Left Side
3
6
1
6
Advertising