THX9321 PRESTIGE

®

2.0 AND THX9421 PRESTIGE

®

IAQ WITH EIM

68-0311—02

46

4080

Outdoor

Temperature used

with Maximum

Cool Recovery

Ramp Rate

Off
-20° F to 100°F

70° F

Commercial No

Off: The cooling system will begin recovery

at the time that is scheduled.

When a Maximum Recovery Ramp Rate is

set, the thermostat will begin recovery

early to ensure the temperature is reached

at the scheduled time.

Set a Maximum Recovery Ramp Rate

based on the rate that the cooling system

can recover at for a mild day in your region.

Default setting is 6° F / hour.

Set an Outdoor Temperature that is

representative of a mild day in your region

to be associated with the Maximum

Recovery Ramp Rate.

The thermostat will begin recovery at the

optimal time based on a calculated ramp

rate, allowing the system to recover on

time and save energy during changing

outdoor conditions.

During recovery, the setpoint changes at a

rate in degrees per hour depending on the

outdoor temperature.

4090

Adaptive Intelligent

Recovery

No
Yes

Yes

Residential

No

No: The system will begin heating or

cooling recovery at the scheduled time.

Yes: The thermostat will begin heating or

cooling recovery early to ensure that the

temperature is reached at the scheduled

time. The thermostat will adjust the start

time of the equipment based on how

quickly the scheduled temperature was

reached on previous days.

4100

Minimum Cool

Setpoint

50° F to 99° F

50° F

Both

No

The user cannot set the temperature below

this level.

4100

Maximum Heat

Setpoint

40° F to 90° F

90° F

Both

No

The user cannot set the temperature above

this level.

4110

Keypad Lockout

Unlocked
Partially Locked
Fully Locked

Unlocked

Both

No

Unlocked: User has access to all

thermostat settings.

Partially Locked: User can modify only

temperature settings.

Fully Locked: User cannot modify any

settings.

4120

Residential:

Entry / Exit Remote

- Home Cool

Setpoint

Commercial:

Entry / Exit Remote

- Occupied Cool

Setpoint

None
50° F to 99° F

Note: setpoint is limited based on

setting at ISU 4100.

75° F

Both

No

The thermostat maintains this Cool setting

when the user presses Home / Occupied at

the Entry / Exit Remote. Select None to

delete this temperature setting. The

thermostat only responds to the Entry / Exit

Remote if a temperature is pre-set at this

screen. See “Wireless Entry/Exit Remote”

beginning on page 128.

Table 4. Installer Setup (ISU) Table. (Continued)

ISU

Number

Installer Setup

Name

Settings

Default

Residential,

Commercial

or Both

Requires

EIM

Notes