1. routine maintenance, 3 months, 3 months 6 months – Hobart Welding Products CYBERSTICK OM-314 User Manual

Page 20: 2. troubleshooting

Advertising
background image

OM-314 Page 16

SECTION 4 – MAINTENANCE & TROUBLESHOOTING

4-1.

Routine Maintenance

.

Maintain more often
during severe conditions.

Y

Disconnect power
before maintaining.

3 Months

Replace

Unreadable

Labels

Repair Or

Replace
Cracked

Weld

Cable

3 Months

6 Months

Clean

And

Tighten

Weld

Terminals

Blow Out

Or

Vacuum

Inside

During Heavy

Service,

Clean Monthly

OR

4-2.

Troubleshooting

Trouble

Remedy

No weld output.

Place Power switch in the On position (see Section 3-1).

Place line disconnect switch in the On position (see Section 2-9).

Check line fuse(s); replace if open or reset circuit breaker(s) (see Section 2-9).

Check for proper input connections (see Section 2-9).

Check for proper jumper link position (see Section 2-9).

Erratic or improper weld output.

Use proper size and type weld cable (see Section 2-6).

Clean and tighten all weld connections (see Section 4-1).

Be sure electrode is dry and proper type for SMAW.

Check connections at input terminal board TE1 (see Section 2-9).

Fan motor FM does not run.

Check line fuse(s); replace if open or reset circuit breaker(s) (see Section 2-9).

Check and clear blocked fan blade.

Have Factory Authorized Service Agent check fan motor.

Low weld output.

Check for proper input connections (see Section 2-9).

Check for proper jumper link positions (see Section 2-9).

Use proper size and type weld cable (see Section 2-6).

Clean and tighten all weld connections (see Section 4-1).

Low weld output; Amperage Adjustment control does
not control weld output.

Reset control circuit overload breaker CB1 (see Section 3-1).

Advertising