Heat & Glo • SL-550 / 750 / 950TR-D • InD • 2044-985 Rev. M • 10/06

16

Figure 5.6

H

2

V

2

H

1

V

1

Top Vent - Horizontal Termination

Venting with 3 elbows (NG)

V Minimum

H

1

+ H

2

Maximum

SL-550TR-D

SL-750TR-D

SL-950TR-D

90 Elbow

2 ft.

610 mm

2 ft.

610 mm

2 ft.

610 mm

0.5 ft. 152 mm

6 ft.

1.8 m

6 ft.

1.8 m

6 ft.

1.8 m

1.5 ft. 457 mm 10 ft.

3.0 m

10 ft.

3.0 m

10 ft.

3.0 m

2.5 ft. 762 mm 12 ft.

3.7 m

12 ft.

3.7 m

12 ft.

3.7 m

3.5 ft.

1.1 m

14 ft.

4.3 m

14 ft.

4.3 m

14 ft.

4.3 m

H + H

1

MAX. =14 FT (4.6 m)

V + V

1

+ H + H

1

MAX. = 40 FT (12.2 m)

V Minimum

H

1

+ H

2

Maximum

SL-550TR-D

SL-750TR-D

SL-950TR-D

90 Elbow

2 ft.

610 mm

Not allowed

Not allowed

0.5 ft. 152 mm

6 ft.

1.8 m

6 ft.

1.8 m

6 ft.

1.8 m

1.5 ft. 457 mm 10 ft.

3.0 m

10 ft.

3.0 m

10 ft.

3.0 m

2.5 ft. 762 mm 12 ft.

3.7 m

12 ft.

3.7 m

12 ft.

3.7 m

3.5 ft.

1.1 m

14 ft.

4.3 m

14 ft.

4.3 m

14 ft.

4.3 m

H + H

1

MAX. =14 FT (4.6 m)

V + V

1

+ H + H

1

MAX. = 40 FT (12.2 m)

Top Vent - Horizontal Termination

Venting with 3 elbows (Propane)

NOTE: There MUST be a 25%
reduction in total H when using
fl ex vent except when using the
simple up and out installation
(see Figure 5.3).

Note: Use SL D- Series
components only.