Figure 5.7

NOTE: If installing a vertical vent/termination off the top of
the appliance, the optional vertical termination baffl e should
be used.

CAP

V

1

V

1

= 44 ft. Max. (13.4 m)

Top Vent - Vertical Termination
No Elbows

Baffl e Instruction

1. Install the baffl e over the center of the exhaust outlet in

the fi rebox (see Figure 5.8).

2. Center the exhaust opening in the open end of the

baffl e, and secure through the slots on the baffl e with
the 2-1/4 in. self tapping screws provided.

Baffl es are recommended for these vertically terminated
products which have excessive draft. Baffl es compensate
for high draft, restore visual fl ame height, and limit exces-
sive cooling resulting from too much secondary air. Refer
to the allowable vent confi gurations in the model specifi c
installer’s guide for recommended use of this baffl e.

Note: Use SL D- Series
components only.

BAFFLE

VIEW FROM

UNDERNEATH

SIDE VIEW

FIREBOX

BACK

EXHAUST

FIREBOX

BACK

BAFFLE

FRONT

OF UNIT

Figure 5.8