Flex vent – Hearth and Home Technologies BE-36-CIPI User Manual

Page 16

Advertising
background image

Hearth & Home Technologies • BE-36-C, BE-36-CIPI • 397-981 Rev. R • 2/05

16

STRAIGHT UP

VERTICAL VENTING

V (FT.)

45' MAX.

Figure 8.

Straight up Vertical Venting

Use SL D-Series

components only.

NOTE: For vertical
venting over 20 feet an
Extended Vertical Baffle
Kit is recommended for
improved flame
appearance.

V

CAP

Figure 7.

Flex Vent

The flex vent must be supported with the spacing between
support intervals not exceeding 4 feet, with no more than ½
inch sag between supports.

A support is required at each change in venting direction,
and in any location where it is necessary to maintain the
necessary clearance to combustibles. A simple “up and out”
installation (Figure 7) requires only enough support to main-
tain the necessary clearance to combustibles. However, the
vent attachment point and the firestop location are consid-
ered to be supports.

3” CLEARANCE

TERMINATION

CAP

FLEX-VENT

1”

CLEARANCE

STRAIGHT OUT HORIZONTAL VENTING

H

Max. Run

36" (914 mm)

Use DVP-Series

components only.

Figure 9.

Straight Out Horizontal Venting

For corner
installation.

45-DEGREE

ELBOW

H

Two 90

0

elbows or one 45

0

elbow may be used for corner
installations. The use of two 90

0

elbows in a corner installation
will affect space requirements
(see Fig. 2)

90-DEGREE

ELBOWS