Hearth and Home Technologies BE-36-CIPI User Manual

Page 22

Advertising
background image

Hearth & Home Technologies • BE-36-C, BE-36-CIPI • 397-981 Rev. R • 2/05

22

Figure 16. Venting with Four 90° elbows

VENTING WITH FOUR (4)

90°

ELBOWS

NATURAL AND PROPANE GAS

V (MIN.) H (MAX.)

2' (609mm) 5' (1.52m)

V

1

(MIN.) H

1

(MAX.) V

2

(MIN.)

5' (1.52m) 5' (1.52m) 4.5' (1.37m)

V + V

1

+ V

2

+ H + H

1

MAX. = 40' (12.2m)

V

H

V

2

V

1

H

1

NOTE: There MUST be a 25% reduc-
tion in total H when using flex vent
except when using the simple up
and out installation (see Figure 7).

Use SL D-Series

components only.