21

Use SL D-Series

components only.

BE-36-C

H + H

1

(MAX.)

4' (1.22m)
6' (1.86m)
8' (2.48m)
12' (3.72m)
16' (4.8m)
16' (4.8m)

Figure 15. Venting with Three 90° elbows

H + H

1

MAX. = 16' (4.8m)

V + H + V

1

+ H

1

MAX. = 40' (12.2m)

BE-36-C LP

H + H

1

(MAX.)

5' (1.52m)
5' (1.52m)
8' (2.48m)
12' (3.72m)
16' (4.8m)
16' (4.8m)

Use SL D-Series

components only.

H + H

1

MAX. = 16 FT (4.8m)

V + V

1

+ H + H

1

MAX. = 40 FT (12.2m)

BE-36-C

V (MIN.)

H + H

1

(MAX.)

90

o

Elbow on Top 2.5' (863mm)

1' (305mm)

3' (914mm)

2' (610mm)

4' (1.22m)

3' (914mm)

6' (1.86m)

4' (1.22m)

8' (2.48m)

5' (1.52m)

16' (4.8m)

BE-36-C LP

H + H

1

(MAX.)

2.5' (863mm)
2.5' (863mm)
4' (1.22m)
6' (1.86m)
8' (2.48m)
16' (4.8m)

V1

H1

H

V

BE-36-C, BE-36-C LP

V (MIN.)

H (MAX.)

90

o

Elbow on Top 2.5' (863mm)

1' (305mm)

2.5' (863mm)

2' (610mm)

4' (1.22m)

3' (914mm)

6' (1.86m)

4' (1.22m)

8' (2.48m)

5' (1.52m)

16' (4.8m)

NOTE: There MUST be a 25% reduc-
tion in total H when using flex vent
except when using the simple up and
out installation (see Figure 7).