INSTALLATION MANUAL FOR INDOOR UNIT

(4) Preparation for suspending the unit

22

990

100

55

225

123

1024

452

225

Standard pressure 0 Pa , Middle pressure 50Pa

1.0m (use white motor plug)
5.0m(use red motor plug)

The distance between the air outlet of duct and the air outlet of air conditioner should be no more than

1.0m(use white motor plug);

The distance between the air outlet of duct and the air outlet of air conditioner should be no more than

5.0m(use red motor plug).

When install the duct hidden type indoor unit, the return air box must be designed and installed, as
Figure3, Figure4.
The distance between the air outlet of duct and the air outlet of air conditioner should be no more than
1m.

(a) Figure of installation dimension: (unit: mm)

There should be
no obstacles
within 1m

Unit

Return air

Return air box

Air outlet grille

(Figure 3)

Ceiling

Air supply

A

Building roof of installation

Air supply

Return air

Return air box

Unit

(Figure 4)