SAFETY PRECAUTIONS

2. If the supply cord is damaged, it must be replaced by the manufacturer or its

service agent or a similar qualified person.

3. If the fuse on PC board is broken please change it with the type of T3.15A /250VAC.

4. The wiring method should be in line with the local wiring standard.

5. Use copper wire only. The connecting cable should be H05RN-F 4G 0.75mm

2

.

The power cable should be H07RN-F 3G 2.5mm

2

. All the cables shall have got the

European allthentication certificate.

6. The power supply connects from the outdoor side.

7. The breaker of the air conditioner should be all-pole switch; and the distance

between its two contacts should be no less 3mm.

8. The indoor unit installation height is at least 2.5m.

1. Applicable ambient temperature range:

The machine is adaptive in following situation

Note:

Part of the power supply of the air conditioner are not prepared because of the

requirement of the dealer, the power supply should be provided for oneself.

5

Cooling

Heating

Indoor

outdoor

Rated Maximum Minimum
27 32 18
19 23 14
35 43 -5
24 26 --
20 27 15
14.5 -- --
7 24 -7
6 18 --

DB C
WB C
DB C
WB C

Indoor

outdoor

DB C
WB C

DB C
WB C