Listing and code approvals, Warning, Caution – Hearth and Home Technologies Fireside Burner/Hearth Kits SP18NG User Manual

Page 4: A. appliance certification, B. table 1

Advertising
background image

Hearth & Home Technologies • Fireside Burner/Hearth Kits • 4004-318 • Rev E 2/2013

4

1

Listing and Code Approvals

A. Appliance Certification

The Fireside Burner/Hearth Kits have been tested and listed

in the U.S. in accordance with

ANSI Z21.60b-2004 (Gas Log

Set). In Canada the Gas Log Hearth Kits have been tested

and approved in accordance with

CGA 2.26b-2004. They

have been listed by OMNI Test Labs for installation and

operation in the United States and Canada as described in

these Installation and Operating Instructions. All components

are UL, OMNI, or CSA safety certified.
Check with your local building code agency prior to installing

this appliance to ensure compliance with local codes,

including the need for permits and follow-up inspections.

In the absence of local codes, comply with the

National

Fuel Gas Code, ANSI Z223.1-Latest Edition in the U.S.;

in Canada, the

CAN/CGA B149 Installation Codes. If any

assistance is required during installation, please contact

your local dealer or call the Technical Services Department

at 1-888-427-3973 or 1-800-927-6841.

B. Table 1

Asphyxiation Risk
This appliance produces carbon monoxide

(CO).

• The free opening areas (in square inches)

of the chimney damper as shown in the

tables must be met.

• User must make sure damper is locked

open.

• The installer is responsible to ensure

proper ventilation of flue gases before

appliance is used.

Fire needs to draft properly for safe

operation.

WARNING

Improper installation, adjustment, alteration, service

or maintenance can cause injury or property damage.

Refer to the owner’s information manual provided with

this appliance. For assistance or additional information

consult a qualified installer, service agency or the gas

supplier.

WARNING

Sharp Edges

• Wear protective gloves

and safety glasses during

installation.

CAUTION

Fire Risk

Exhaust Fumes Risk

• Do NOT use this appliance as a “vent-free

heater.

The flue must be permanently open. Refer

to Table 1.

WARNING

Product

SP18NG

SP18LP

SP24NG

SP24LP

SP30NG

SP30LP

STSP18NG

STSP18LP

STSP24NG

STSP24LP

Inlet BTU / KW /HR

Nat. 60,000 / 17.6

67,000 / 19.6

80,000 / 23.4

60,000 / 17.6

75,000 / .22

LP

40,000 / 11.7

40,000 / 11.7

60,000 / 17.6

65,000 / 19

69,000 / 20.2

Manifold Pressure IN.

WC/ KPa

Nat.

3.5 / .018

3.5 / .018

3.5 / .018

3.5 / .018

3.5 / .018

LP

11.0 / 0.057

11.0 / 0.057

11.0 / 0.057

11.0 / 0.057

11.0 / 0.057

Max. Inlet Pressure

IN. WC / KPa

Nat.

10.0 / .052

10 / .052

10 / .052

10.0 / .052

10 / .052

LP

13.0 / 0.068

13.0 / 0.068

13.0 / 0.068

13.0 / 0.068

13.0 / 0.068

Min. Inlet Pressure IN.

WC / KPa

Nat.

3.5 / .018

3.5 / .018

3.5 / .018

3.5 / .018

3.5 / .018

LP

11.0 / 0.057

11.0 / 0.057

11.0 / 0.057

11.0 / 0.057

11.0 / 0.057

Orifice Size

In. / mm

Nat. (#26) .147

(#20) .161

(#16) .177

(#24) .152

(#20) .161

LP

(#47) .078

(#47) .078

(#42) .0935

(#45) .082

(#42) .0935

Minimum Fireplace

Opening Size

In. / cm

Front

28 / 71.1

28 / 71.1

34 / 86.4

34 / 86.4

42 / 106.7

42 / 106.7

-

-

34 / 86.4

34 / 86.4

Rear

16 / 40.6

16 / 40.6

18 / 45.7

18 / 45.7

24 / 61.0

24 / 61.0

-

-

-

-

Depth

14 / 35.6

14 / 35.6

16 / 40.6

16 / 40.6

16 / 40.6

16 / 40.6

16 / 40.6

16 / 40.6

16 / 40.6

16 / 40.6

Height

16 / 40.6

16 / 40.6

18 / 45.7

18 / 45.7

20 / 50.8

20 / 50.8

18 / 45.7

18 / 45.7

18 / 45.7

18 / 45.7

Min. Vent Opening in

Square In. / cm

39 / 251.6

39 / 251.6

48 / 309.7

48 / 309.7

58 / 374.2

58 / 374.2

39 / 251.6

39 / 251.6

48 / 309.7

48 / 309.7