A. Gas Supply Connection

A 3/8 in. flared fitting has been installed on the gas valve

inlet at the factory. Ensure fittings are of the appropriate size

and type on the gas line connection. If the tubing has to be

cut to length be sure to use the proper cutting and flaring

tool. Also, be careful not to crimp the tubing while bending. If

the tubing becomes crimped, do not use for installation.

Fire Risk

Explosion Risk
Verify inlet pressures.

• High pressure may cause over fire

condition.

• Low pressure may cause explosion.
Install regulator upstream of valve if line

pressure is greater than 1/2 psig.

WARNING

3

Appliance Preparation

• Remove black cap from left side.

• Remove two pilot head screws.

• Remove two pilot bracket screws.

• Detach thermocouple and pilot from control valve.

• Remove the control valve from the right side of the burner

pan and replace on left, upside down.

Note: Prior to installing the valve, use Teflon tape or joint

compound on the male threads.

• Reinstall pilot bracket on left side of burner.

• Reinstall pilot assembly to pilot bracket.

• Reattach pilot tube and thermocouple to control valve.

• Reinstall black cap removed from left side of burner to

right side.

• Install valve shield.

Note: An individual manual shutoff valve (not supplied) is

required when installing this appliance. The manual shutoff

valve must be located in an easily accessible area, no more

than 6 feet from the appliance.

Note: Have the gas supply line installed in accordance

with local building codes, if any. If not, follow

ANSI 223.1.

Installation should be done by a qualified installer approved

and/or licensed as required by the locality. (In the Common-

wealth of Massachusetts installation must be performed by

a licensed plumber or gas fitter.)

Note: A listed (and Commonwealth of Massachusetts

approved) 1/2 in. (13 mm) T-handle manual shut-off valve

and flexible gas connector are connected to the 1/2 in.

(13 mm) control valve inlet.
• If substituting for these components, please consult

local codes for compliance.

Shock Risk

Fire Risk
Use ONLY optional accessories approved

for this appliance.

• Using non-listed accessories voids

warranty.

• Using non-listed accessories may result

in a safety hazard.

• Only Hearth & Home Technologies

approved accessories may be used

safely.

WARNING

WARNING

Gas Leak Risk

• Support control when attaching pipe to

prevent bending gas line.

Fire Risk

Explosion Risk

Personal Injury Risk
An explosion could occur if a connection is

made directly to an unregulated propane (LP)

tank.

WARNING

Joint compound to Teflon tape must be used on all threaded

male connections to ensure a tight seal.

LP Only

• Install new pilot bracket on left side of burner.

• Install new pilot assembly to pilot bracket.

• Attach pilot tube and thermocouple to control valve.

• Install black cap removed from left side of burner to right

side.

• Install valve shield.

Natural Only

NOTE: You will need a kit to change to

left side piping. See page 18.

Left side piping when finished

B. Convert to Left Side Piping

Advertising