13. installing alternative plug, 14. cable management strap – Hobart Welding Products AIRFORCE 700I User Manual

Page 21

Advertising
background image

.

A complete Parts List is available at www.MillerWelds.com

OM-244 013 Page 17

4-13. Installing Alternative Plug

1

Supplied 230 VAC Plug

Cut cord close to plug.

2

Alternative Plug (230 VAC
Plug Shown)

3

Input (Black Lead)
(Brass) Terminal

4

Input (White Lead)
(Brass) Terminal

5

Ground (Green) Terminal

6

Outer Shell

7

Cord Grip

Strip cord jacket back enough to
separate conductors.
Strip conductors enough to make
good contact with plug terminals.
Make plug connections and reinstall
outer shell and cord grip. Tighten
assembly screws onto shell. Do not
overtighten.

Ref. 801 305-A / 801 611

.

This procedure is necessary if the unit is to be connected
to a 208/230 VAC receptacle that requires a plug that is
different from the supplied plug.

Tools Needed:

1

6

7

2

3

4

5

4-14. Cable Management Strap

244 413-A / 244 412-A

1

Cable Management Strap

Coil cables together and secure to
unit using the cable management
strap.

1

1

Advertising