Caution, Installer setup, Temperature settings – Honeywell CHRONOTHERM IV DELUXE T8624D User Manual

Page 7

Advertising
background image

T8624D CHRONOTHERM

®

IV DELUXE PROGRAMMABLE THERMOSTAT

68-0166—1

7

NOTE:

Always press the keys with your fingertip or similar
blunt tool. Sharp instruments like a pen or pencil
point can damage the keyboard.

Temperature Settings

Refer to Table 5 for the default program. If the daytime energy
savings period is not used, press the period key (Leave or
Return) until the time is blank. The fan setting feature is
available on select thermostat models. See Programming
Section for complete instructions on changing the program.

Table 5. Default Program Settings.

To change a setting, use the increase

or

decrease

key.

To scroll the Installer Setup numbers backwards, press
the Time

key.

To exit the Installer Setup, press Run Program.

INSTALLER SETUP

NOTE:

For most applications, the thermostat factory
settings will not need to be changed. Review the
factory settings in Table 6 and if no changes are
necessary, go to the Installer System Test section.

The Installer Setup is used to customize the thermostat to
specific systems. Some of the options include temperature
display, changeover and outdoor temperature display. Installer
Setup numbers are listed in Table 6. The table includes all the
configuration options and the factory settings for the
thermostat.

A combination of key presses are required to use the Installer
Setup feature.

To enter the Installer Setup, press and hold the
Information

i

key with the increase

and decrease

keys until the first number is displayed. All display
segments appear for approximately three seconds before
the number is displayed. See Fig. 8 and 9.

To advance to the next Installer Setup, press the
Time

key.

Period

Time

Heat

Setpoint

Cool

Setpoint

Fan

Setting

Wake

6:00 AM

70°F

(21°C)

78°F

(25.5°C)

Auto

Leave

8:00 AM

62°F

(16.5°C)

85°F

(29.5°C)

Auto

Return

6:00 PM

70°F

(21°C)

78°F

(25.5°C)

Auto

Sleep

10:00 PM

62°F

(16.5°C)

82°F

(28°C)

Auto

Fig. 8. Display of all the segments of the LCD.

Fig. 9. Display of Installer Setup number and setting.

CAUTION

Electric heat systems must be configured to 1 in
Installer Setup number 2 to prevent equipment
damage caused by the system running without
the fan.

IMPORTANT

Only configurable numbers are shown on the
device. Example: If thermostat does not have a
system key, Installer Setup Number 12 will not be
displayed. Review Table 6 factory settings and mark
any desired changes in the Actual Settings column.
When Installer Setup is complete, review the
settings to confirm that they match the system.

Aux Ht

Heat

Auto

System

Fan

Off

Auto

Wake

Mon

Wait

In

Room

Outdoor

%Humid

Auto

Sav

AM

PM

Hold for

Cool

Repl Batt

On

Recovery

DST

Cool

TueWedThuFriSatSun

LeaveReturnSleep

M10345

Set Program

Set Day/Time

Start Time

Temporary Setting Enrg

Em Heat

Em Ht

M10404

INSTALLER SETUP
NUMBER DISPLAY
(COLUMN 2
OF TABLE 6)

FACTORY SETTING
OR OTHER CHOICE
DISPLAY (COLUMN 3
OR 5 OF TABLE 6)