6. MENU FUNCTIONS

• Direction

Specify to the right, left, guide 1 or guide 2
depending on which direction the area lies from
the charging station. The direction is set
looking at the charging station in the approach
direction of the mower.

When a guide wire is installed the direction can
be specified as the guide wire. The mower will
now follow the selected guide wire instead of
the boundary wire.

• Distance

Specify the number of metres along the
boundary wire or guide wire from the charging
station to the place in the remote area where
the mower shall start mowing.

Tip!

Use the Test OUT (3-2-5) function (see

page 55) to find out how far it is to the remote
area. The distance, stated in meters, will appear
on the mower display.

• Proportion

Specify a value for how often of the occasions
Automower

®

leaves the charging station it

should follow the loop out to the remote area.

For example the value 20 % means that in 20 %
of the occasions Automower

®

leaves the

charging station, it does it in the direction to the
remote area. In the remaining 80 % of the
occasions the mower leaves the charging station
according to the setting made for its function Exit
angles (3-1)
.

If a value of 20 % is specified for Area 1 and
10 % for Area 2, the remaining 70 % is allocated
to the selection under Exit angles (3-1).

Follow loop in (3-2-2)

This function is used to control how Automower

®

searches for the charging station.

Automower

®

always starts the search for the

charging station in an irregular search method. In
some gardens this is not sufficient for the mower
to quickly find the charging station. The search
can then be epitomized using the Follow loop in
function.

When the mower still can not find the charging
station after a specific period of irregular
searching, it also starts to search for the guide
wires and after a further period also the boundary
wire to follow one of them into the charging
station instead. This time is stated in minutes, and
delays searching for guide 1, guide 2 and the
boundary wire.

The delay time can be adapted to the shape of the
garden in the Follow loop in function.

Direction

Distance

Proportion

Area 1

Area 2

Area 3

Area 4

Area 5

Right

Left

Guide 1

Guide 2

Direction

Distance

Proportion

3-2

3-2-2

Exit angles

Follow loop

Installation shape

Advanced

Follow loop out

Follow loop in

Corridor width

Test IN

Test OUT