17

HORIZONTAL VENTING

Kit No.

H Max. Run

DVP-TRAP

24" (610 mm)

Figure 11. Corner Installation

NOTE: This model is tested and approved to

use 45° elbows in corner installations. Howev-

er, 90° elbows will result in better performance.

3. Match the amount of vertical you have in the sys-

tem with the chart to find the appropriate position

to set the Flue Restrictor (see Figure 9).

1 2 3 4 5

SETTINGS

1 2 3 4 5

Figure 10

4. Center the Flue Restrictor on vent and secure in

place by using two self-tapping screws (see Fig-

ure 10).

5. Reinstall the Exhaust Shield.

- CHART -

Vertical

Top Vent

NG

Top Vent

LP

Rear Vent

NG

Rear Vent

LP

4'

1-1

No

Restrictor

No

Restrictor

No

Restrictor

8'

2-2

1-2

1-1

No

Restrictor

15'

3-3

3-2

2-2

1-2

20'

3-4

3-3

3-3

2-3

25'

3-4

3-3

3-3

2-3

30'

4-4

3-4

3-4

3-3

35'

4-4

3-4

3-4

3-3

40'

5-4

4-4

4-4

3-4

Figure 9.

H

45-DEGREE

ELBOW

90-DEGREE

ELBOWS

Н

Advertising
This manual is related to the following products: