Heat & Glo • 6000TR-OAK, 6000TR-OAK-IPI • 383-901 Rev. K • 5/06

23

3. Continue Adding Vent Components

WARNING: INSTALLATION OF THIS FIREPLACE

REQUIRES THE USE OF HEAT SHIELD 570-290

ABOVE THE FIRST 90

0

ELBOW IN THE VENTING

SYSTEM.

Figure 20

To Install the Heat Shield:
1. Determine if the heat shield is required. Do so by mea-

suring the vertical distance between the top horizontal

surface of the elbow to any combustible surface above.

If the distance is more than 4 inches, the heat shield is

NOT required. If it is 4 inches or less, the heat shield IS

REQUIRED. Install per the following steps. See Figure 20.

Figure 21

CORRECT

INCORRECT

2. Fasten the shield in place using the four pilot holes pro-

vided in the part. The shield should be oriented such that

the 13 1/8 inch dimension (longest dimension) is run-

ning in the same direction the elbow is pointing. The

shield should be centered directly above the elbow, and

positioned so that it creates a 1/2 inch airspace between

the shield and the combustible surface. See Figure 21.

COMBUSTIBLE SURFACE

DIRECTION

UP

HEAT SHIELD

90 ELBOW

0

Figure 22

• If the combustible materials are not in place at the time

of install the elbow heat shield may be screwed to the

exhaust pipe (see Figure 22). Cut the tabs as shown

and bend down. Secure the heat shield to the pipe main-

taining 3” to 4” between the pipe and shield.

Refer to Cinch Pipe and Termination Cap installation in-

structions.
• Continue adding vent components, locking each succeed-

ing component into place.

• Ensure that each succeeding vent component is secure-

ly fitted and locked into the preceding component in the

vent system.

• 90° elbows may be installed and rotated to any point

around the preceding component’s vertical axis. If an el-

bow does not end up in a locked position with the pre-

ceding component, attach with a minimum of two (2)

sheet metal screws.

3”

(76mm)

SCREW

4. Install Support Brackets
Refer to Cinch Pipe and Termination Cap installation in-

structions.

HEAT

SHIELD

3” MIN.

(76mm)

COMBUSTIBLE

SURFACE