Installing the Fireplace

Step 1. Locating the Fireplace

The following diagram shows space and clearance require-

ments for locating a fireplace within a room.

A

B

C

D

E

42”

22”

36”

51”

72”

Note*

42”

22”

40”

57”

80”

Minimum Clearances

from the Fireplace to Combustible Materials

Inches

mm

Glass Front ........................ 36 .................... 914

Floor ................................... 0 ....................... 0

Rear ...................................1/2 ..................... 13

Sides .................................1/2 ..................... 13

Surround Sides* .................. 0 ....................... 0

Top ................................... 3 1/2 ................... 89

Ceiling** ............................. 31 .................... 787

Figure 2. Fireplace Dimensions, Locations,

and Space Requirements

Minimum Clearances

from the Vent Pipe to Combustible Materials

Inches

mm

Vertical Sections. ............. 1 ................ 25
Horizontal Sections

Top ..................................... 3 ................ 75

Bottom ............................... 1 ................ 25

Sides ................................. 1 ................ 25
At Wall Firestops

Top .................................. 2 1/2 ............ 63.7

Bottom .............................. 1/2 ............... 13

Sides ................................. 1 ................ 25

* See Figure 3.

** The clearance to the ceiling is measured from the top

of the unit, excluding the standoffs (see Figure 38).

The distance from the unit to combustible construction

is to be measured from the unit outer wrap surface to

the combustible construction,

NOT from the screw heads

that secure the unit together.

For minimum clearances, see the direct vent termination

clearance diagrams on pages 24 and 25 in this manual.

1/2” MIN. (13mm)

D

C

E

B

1” MIN. (25mm)

A

Clearance Requirements
The top, back, and sides of the fireplace are defined by

stand-offs. The minimum clearance to a perpendicular wall

extending past the face of the fireplace is one inch (25 mm).

The back of the fireplace may be recessed 21 1/2 inches

(546 mm) into combustible construction.

Constructing the Fireplace Chase

A chase is a vertical box-like structure built to enclose the

gas fireplace and/or its vent system. Vertical vents that run

on the outside of a building may be, but are not required to

be, installed inside a chase.

CAUTION: TREATMENT OF FIRESTOP SPACERS AND

CONSTRUCTION OF THE CHASE MAY VARY WITH THE

TYPE OF BUILDING. THESE INSTRUCTIONS ARE NOT

SUBSTITUTES FOR THE REQUIREMENTS OF LOCAL

BUILDING CODES. THEREFORE, YOUR LOCAL BUILD-

ING CODES

MUST BE CHECKED TO DETERMINE THE

REQUIREMENTS FOR THESE STEPS.

Factory-built fireplace chases should be constructed in the

manner of all outside walls of the home to prevent cold air

drafting problems. The chase should not break the outside

building envelope in any manner.

This means that the walls, ceiling, base plate and cantile-

ver floor of the chase should be insulated. Vapor and air

infiltration barriers should be installed in the chase as per

regional codes for the rest of the home. Additionally, in re-

gions where cold air infiltration may be an issue, the inside

surfaces may be sheetrocked and taped for maximum air

tightness.

To further prevent drafts, the wall shield and ceiling firestops

should be caulked with high temperature caulk to seal gaps.

Gas line holes and other openings should be caulked with

high temp caulk or stuffed with unfaced insulation. If the

appliance is being installed on a cement slab, a layer of

plywood may be placed underneath to prevent conducting

cold up into the room.

THE CHASE SHOULD BE CONSTRUCTED SO THAT ALL

CLEARANCES TO THE FIREPLACE ARE MAINTAINED

AS SPECIFIED WITHIN THIS INSTALLERS GUIDE.

*If venting with (2) 90

0

elbows off rear of unit

the dimensions C, D, and E, will change.