Honeywell Q674F User Manual

Recycling notice, Application, Operation

Advertising
background image

X-XX UL

INSTALLATION INSTRUCTIONS

Copyright © 1995 Honeywell Inc. • • All Rights Reserved

T874G,R Multistage Heat Pump Thermostats

and Q674F,J,L Subbases

APPLICATION

The T874G,R Thermostats with Q674F,J,L Subbases
provide 24 to 30 Vac control of a two-stage heating/one-

stage cooling heat pump system. See Table 1 for
thermostat/subbase specifications.

Table 1. Thermostat/Subbase Specifications.

Switching

Thermostat/Subbase

System

Fan

Changeover

T874G/Q674F

OFF-EM.HT.-HEAT-AUTO-COOL

AUTO-ON

Auto and Manual

T874G/Q674J

EM.HT.-AUTO-OFF

AUTO-ON

Auto

T874R/Q674L

EM.HT.-HEAT-OFF-COOL

AUTO-ON

Manual

OPERATION

On a two-heat thermostat, the two stages of heat

make

sequentially as the temperature drops.

Make

refers to the

mercury switch initiating a call for heat or cool.

There are about 2

°

F (1

°

C) between stages so that the

second stage makes only when the first stage cannot
handle the load. This is the

interstage differential

.

LEDs (light emitting diodes) are included on your subbase.
Refer to the list below for specific meaning.

The CHECK LED lights when something needs to be
checked or done to maintain efficient operation of the
system. See your heating system instructions for the
specific meaning.

The SYSTEM LED lights when the system is calling for
heating or cooling.

The AUX. HT. LED lights when the auxiliary heat (second
stage) is operating. Auxiliary heat operates when the heat
pump alone cannot handle the load.

The EM. HT. LED lights when the system switch is placed
in the EM. HT. position. Emergency heat is operating; in
most systems, the compressor has failed and the heat
pump is not operating.

LEDs are not field replaceable or addable.

RECYCLING NOTICE

This control contains mercury in a sealed tube. Do
not place the control in the trash at the end of its
useful life.

If this control is replacing a control that contains
mercury in a sealed tube, do

not

place your old

control in the trash.

Contact your local waste management authority for
instructions regarding recycling and the proper
disposal of this control, or of an old control
containing mercury in a sealed tube.

INSTALLATION

When Installing this Product…

1. Read these instructions carefully. Failure to follow

them could damage the product or cause a
hazardous condition.

2. Check the ratings given in the instructions and on

the product to make sure the product is suitable for
your application.

3. Installer must be a trained, experienced service

technician.

4. After installation is complete, check out product

operation as provided in these instructions.

69-0268-11