background image

The diagram below shows how to properly position,
level, and secure the fireplace.

1. Place the fireplace

into position.

2. Level the fireplace

from side to side and
from front to back.

3. Shim the fireplace

with non-combustible
material, such as
sheet metal, as
necessary.

4. Secure the fireplace to

the framing by nailing
or screwing.

Figure 8. Proper Positioning, Leveling, and

Securing of a Fireplace

Step 5
Positioning,
Leveling, and
Securing the
Fireplace

!

!

Intermittent Pilot Ignition (IPI) System
This system includes 3V control valve, electronic
module and intermittent pilot.

WARNING: 110-120 VAC MUST NEVER
BE CONNECTED TO A CONTROL
VALVE IN A MILLIVOLT SYSTEM.

WARNING: THIS UNIT IS NOT FOR USE
WITH SOLID FUEL.

Step 6
The Gas Control
System

NAILING TABS

AT BASE OF

FIREPLACE.

Heat & Glo • ST-42TVFL-IPI • 455-902 Rev. C • 12/07