Heat & Glo • ST-42TVFL-IPI • 455-902 Rev. C • 12/07

If the box is being wired to a wall mounted switch for use
with a fan (See Figure 11):

The power supply for the appliance must be brought
into a switch box.

The power can then be supplied from the switch box to
the appliance using a minimum of 14-3 with ground
wire.

At the switch box connect the black (hot) wire and red
(switch leg) wire to the wall switch as shown.

At the appliance connect the black (hot), white (neutral)
and green (ground) wires to the junction box as shown.

Add a 1/4 inch insulated female connector to the red
(switch leg) wire, route it through the knockout in the
face of the junction box, and connect to the top fan
switch connector (1/4 inch male) as shown.

Wall Switch Installation for Fan (Optional)

Red

Red

Black

Black

Green

Green

White

White

Red Black

Green

White

SWITCH BOX

JUNCTION BOX

POWER

SUPPLY WIRES

SWITCH

MINIMUM 14-3 AWG

WITH GROUND

Figure 11. Junction Box Wired to Wall Switch

21