Figure 10. Intermittent Pilot Ignition (IPI) Wiring Diagram

For Intermittent Pilot Ignition (IPI) Wiring

Appliance Requirements

This appliance requires that 110-120 VAC be wired to
the junction box. Maintain correct polarity when wiring
the junction box.

Operation using Battery Power

This fireplace has an optional battery operation. The
system is fully functional with the use of two “D” size
batteries without ordinary 110-120 VAC power.

Wiring to the battery pack should be left disconnected
in order to conserve battery life. In the case of a loss of
power, simply connect red and black wire leads to
activate battery power (connect red to red, black to
black). The fireplace can be used as necessary. Once
power (110 VAC) is restored, disconnect red and black
wire leads to extend battery life.

GREEN

ORANGE

ORANGE

WHITE

GROUND TO FIREPLACE CHASSIS

INTERMITTENT

PILOT IGNITOR

IGNITION

MODULE 3 VAC

TRANSFORMER 3V

BATTERY PACK

HI LIMIT SENSOR

PIGTAIL

CONNECTOR

VALVE

JUNCTION BOX

BROWN

BROWN

BLACK

RED

I

S

REMOTE

RECEIVER