Top view – Heat & Glo Fireplace ST-42TVFL-IPI User Manual

Page 9

Advertising
background image

Figure 3. Fireplace Locations and Space
Requirements

Clearance Requirements

The top, back, and sides of the fireplace are
defined by stand-offs.

Minimum Clearances from the Fireplace to

Combustible Materials

Glass

Back of

Metal Ends

Top of

Sides

Floor

Fireplace

of Fireplace

Fireplace

Ceiling

36 inches

0

1/2 inch

1/2 inch

4-1/2 inches

36 inches

(914 mm)

(13 mm)

(13 mm)

(114 mm)

(914 mm)

The clearance to the ceiling is measured from the top
of the unit, excluding any standoffs (see Step 10
Finishing).

The minimum clearance to a perpendicular wall
extending past the face of the fireplace is one inch
(25mm).

The metal end(s) of these fireplaces may NOT be
recessed into combustible construction.

3

Installing the
Fireplace

Step 1
Locating the
Fireplace

The diagram below shows space and clearance
requirements for locating a fireplace within a room.

9

Heat & Glo • ST-42TVFL-IPI • 455-902 Rev. C • 12/07

36"

GLASS

GLASS

1"

TOP

VIEW

36"