Step 1.
Determine the desired location of the appliance. Check to
ensure that wall studs or roof rafters are not in the way when
the venting system is being planned. If this is the case, you
may want to adjust the location of the appliance.

F. Horizontal Termination

Figure 5.3

Step 2.
Direct vent pipe is designed with a locking connection. To
connect the venting system to the appliance flue outlet, a
twist-lock adapter is built into the appliance at the factory.
Wall thickness may vary. Remember to include wall thickness
in minimum clearances when figuring venting lengths for
your installation needs.

Note: Female ends of direct vent pipe/elbows are designed
to slide straight onto the male ends of adjacent pipes by
orienting the pipe indentations so they match and slide into
the entry slots on the male ends, see

Figure 5.4. Push

the pipe sections completely together, then twist-lock one
section clockwise approximately one-quarter turn, until the
two sections are fully locked. The female locking lugs may
not be visible from the outside. They may be located by
examining the inside of the female ends.

Type A - Up & Out Installation

Type C - 45° Elbow in Corner Installation

Type B - Straight Out Installation

45° Elbow

3/8 in. (10mm) Clearance from
stove corner to combustible wall.

3/8 in. (10mm)
Clearance from
stove corner to
combustible wall
(for valve access
on side).

Wall Thimble/Heat Shield

WALL THIMBLE/

HEAT SHIELD

WALL THIMBLE COVER

PIPE LENGTH

PIPE LENGTH

TERMINATION CAP

CENTER LINE

90° ELBOW

CENTER
LINE

WALL THIMBLE COVER

PIPE LENGTH

SNORKEL KIT

WALL STRAP 14 in. (356mm) Wide

WALL THIMBLE / HEAT SHIELD

15-5/8 in.

(397mm)

21 in.

(533mm)

Fire Hazard.

Exhaust Fume Risk.

Impaired Performance of Appliance.

WARNING

• Ensure vent components are locked together correctly.

• Pipe may separate if not properly joined.

Female Locking Lugs

Male Locking Lugs

Figure 5.4

Fire Risk.

Explosion Risk.

Combustion Fume Risk.
Use vent run supports per installation instructions.

Connect vent sections per installation instructions.

• Maintain all clearances to combustibles.

• Do NOT allow vent to sag below connection

point to appliance.

• Maintain specifi ed slope (if required).

WARNING

Improper support may allow vent to sag or separate.