M. Optional Blower

Figure 8.27

From the rear of the appliance, slide the blower

into the blower housing with the magnetic strips down. The
blower openings should be at the front.

Plug blower power cord into fan outlet on junction box.

The GFK-160A blower has been designed to circulate room
air through the appliance to enhance heat output.

The blower system operates on 120 VAC, 60 Hz power. This is
available through a receptacle in the factory installed junction
box on the underside of the appliance.

KIT CONTENTS: Blower; speed control; lock nut; control
knob; ground clip; temperature sensor switch; wing nut; 2
high-temp black wires; 1 high-temp blue wire.

TOOLS REQUIRED: Philips head screwdriver; 1/2 in.

wrench.

Figure 8.26

Compare CONTENTS OF CARTON with the

actual parts received. If any parts are missing or damaged,
contact your dealer before starting installation. Do not install
a damaged blower kit.

BLOWER

CONTROL

KNOB

GROUND

CLIP

CONTROL

NUT

SPEED

CONTROL

WING

NUT

TEMP.

SENSOR

SWITCH

Figure 8.28

Attach grounding clip supplied with the kit to the

blower housing. Attach ground wire to grounding clip.

WING NUT

Figure 8.30

Remove valve access cover from back of

appliance by removing the three screws indicated.

3

SCREWS

Figure 8.29

Slide temperature sensor switch/bracket assembly

onto the 10-32 screw located on the left underside of the
appliance. Secure the bracket assembly with the wing nut
provided.

Disconnect the two wire ends connected together on the
junction box. Connect female end to one side of temperature
sensor switch.

Connect one end of the black wire provided with the kit to the
remaining wire end on junction box.

Feed loose ends of the black and blue wires through the
orange grommet in fan housing.