Step 1.
Check the installation instructions for required 1 in. (25mm)
clearances (air space) to combustibles when passing through
ceilings, walls, roofs, enclosures, attic rafters, or other nearby
combustible surfaces. See page 17,

Figure 5.15. Check the

instructions below for maximum vertical rise of the venting
system, and any maximum horizontal offset limitations. All
offsets must fall within the set parameters of the vent graph
(

Figure 5.2) located on page 12.

NOTE: Maximum vertical rise allowable is 35 ft. (11m),
Figure 5.11.

NOTE: Maximum number of 45° elbows permitted for a
vertical installation is eight, provided their installation does
not decrease maximum allowable horizontal run (as specified
by vent graph, on page 12).

Plumber’s Tape
connected to
Wall Strap

Wall Strap

Two 45˚ Elbows

Step 2.

S

et the gas appliance in its desired location. Drop a plumb

bob down from the ceiling to the position of the appliance
flue exit, and mark the location where the vent will penetrate
the ceiling. Drill a small hole at this point. Next, drop a plumb
bob from the roof to the hole previously drilled in the ceiling,
and mark the spot where the vent will penetrate the roof.
Determine if ceiling joists, roof rafters, or other framing will
obstruct the venting system. You may wish to relocate the
appliance, or to offset, as shown in

Figure 5.12 to avoid

cutting loadbearing members.

G. Vertical Termination

1. Direct Vent Pipe

Figure 5.10

Figure 5.11

Figure 5.12

VERTICAL

TERMINATION

CAP

STORM

COLLAR

FLASHING

FIRESTOP

PIPE

LENGTH

SUPPORT

BOX

35 ft. (11m)
MAXIMUM

Fire Risk.

Explosion Risk.

Maintain vent clearance to combustibles as speci-
fi ed.

WARNING

• Do not pack air space with insulation or other

materials.

Failure to keep insulation or other materials away
from vent pipe may cause fi re.